# Configure a Dissolution Tester FLA Path

[llms-txt]: # "For AI agents: the complete documentation index is at https://developers.tetrascience.com/llms.txt — markdown versions of any page are available by appending .md to the URL."

This quickstart guide shows how to configure a [Tetra File-Log Agent](https://developers.tetrascience.com/docs/file-log-agent) scan path for a dissolution tester after the Agent is [installed and connected to the Tetra Data Platform (TDP)](https://developers.tetrascience.com/docs/upload-instrument-data-using-a-tetra-file-log-agent#prerequisites).

# Configure a Scan Path for a Dissolution Tester

To configure a Tetra File-Log Agent scan path for a dissolution tester, do the following:

1. [Open the Agent's Details page](https://developers.tetrascience.com/docs/upload-instrument-data-using-a-tetra-file-log-agent#step-1-access-the-agent-details-page).
2. Select the **Configuration** tab. The Agent's configuration information appears.
3. For **Start Date**, enter the date you want to begin using the configuration. If an **End Date** (optional) is specified, only files with last modified dates that are on or after the Start Date and on or before the End Date are uploaded.
4. For **File Change Interval (Seconds)**, enter the minimum time a file in the configured path must remain unchanged before it can be uploaded. The default is `30` seconds.
5. For **Scan Interval (seconds)**, enter the frequency that you want to have between when paths are rescanned for new or changed files. The default is `30` seconds.

> 📘 NOTE
>
> For Tetra File-Log Agent v4.4.x and earlier, there's only a **File Change Interval (Seconds)** setting.

6. Select **New Path**.

7. For **Path**, enter the Dissolution Tester's output directory path. The following are example paths for common dissolution testing systems:
   * **Agilent 708-DS:** `C:\708-DS\Data\*` or `\\AGILENT-DT\708-DS\Data\*`
   * **ERWEKA DT Series:** `C:\ERWEKA\Data\*` or `\\ERWEKA-DT\Data\*`
   * **Sotax AT/DT Series:** `C:\Sotax\WinSOT\Data\*` or `\\SOTAX-DT\WinSOT\Data\*`
   * **Distek Symphony:** `C:\Symphony\Data\*` or `\\DISTEK-DT\Symphony\Data\*`
   * **Pharma Test PTW Series:** `C:\PTW\Data\*` or `\\PHARMATEST-DT\PTW\Data\*`

8. *(Optional)* For **Source Type**, you have the option to enter a name for the data source without spaces. However, it's recommended that you use the **Labels** setting to update files and trigger pipelines, since the **Source Type** setting can't be reconfigured after a file is uploaded.
   Source type Examples:
   * `agilent-708ds` for Agilent 708-DS systems
   * `erweka-dt` for ERWEKA DT series systems
   * `sotax-winsot` for Sotax WinSOT software
   * `distek-symphony` for Distek Symphony systems
   * `pharmatest-ptw` for Pharma Test PTW series

9. For **File Watch Mode**, enter `File` or `Folder`, based on your use case.

10. For **Patterns**, enter a [Glob pattern](https://developers.tetrascience.com/docs/common-glob-pattern) to filter the target file or folder. Glob patterns are a set of wildcard characters. For more information about Glob patterns, including examples, see [Common Glob Patterns](https://developers.tetrascience.com/docs/common-glob-pattern). The following are common Dissolution Tester file types by vendor:

* **Agilent 708-DS:** `*.xls,*.xlsx,*.csv,*.txt,*.pdf,*.xml`
* **ERWEKA:** `*.csv,*.txt,*.xls,*.xlsx,*.pdf`
* **Sotax:** `*.csv,*.txt,*.xls,*.xlsx,*.pdf,*.dat`
* **Distek:** `*.csv,*.txt,*.xls,*.xlsx,*.pdf,*.xml`
* **Pharma Test:** `*.csv,*.txt,*.xls,*.xlsx,*.pdf`
* **Generic formats:** `*.csv,*.txt,*.xls,*.xlsx,*.pdf,*.xml`

11. For **Labels**, either enter new [labels](https://developers.tetrascience.com/docs/basic-concepts-metadata-tags-and-labels#labels) (`name : value` pairs) or select existing ones to annotate files and trigger pipelines without changing any file data. For more information and best practices, see [Labels](https://developers.tetrascience.com/docs/basic-concepts-metadata-tags-and-labels#labels). For a list of recommended labels, see [Recommended Labels](https://tetrascience.zendesk.com/hc/en-us/articles/29736256140301-Recommended-Labels). Consider adding dissolution tester-specific labels such as:

* `instrument_type: dissolution_tester`
* `dissolution_vendor: [agilent/erweka/sotax/distek/pharmatest]`
* `test_type: [usp_apparatus_1/usp_apparatus_2/usp_apparatus_3/usp_apparatus_4]`
* `dissolution_medium: [water/buffer/hcl/phosphate]`
* `sample_type: [tablet/capsule/powder/suspension]`

> **NOTE**
>
> **(For TDP v4.3.2 and higher)** Five labels are applied by default, but can be removed: **vendor**, **software**, **instrument\_type**, and **instrument\_model**, and **instrument\_serial\_number**. Pre-defined values for these five labels are fetched from Tetra Catalog. Users may select from those values or enter their own if the value is not present in the dropdown.

11. For **Symlink Behavior** (required for Agent v4.4.1 and higher), determine how the Agent handles file symbolic links by choosing one of the following options:
    * **Legacy:** When the Agent scans a file symbolic link, it will record the metadata of the symbolic link itself. Then, when uploading the file, the Agent follows the link and uploads the contents of the target file.
    * **Ignore:** The Agent skips file symbolic links entirely during scan and event handling. The Agent doesn't record any metadata for these files and doesn't upload them. Directory symbolic links are still followed.

12. For **Fetch OS File/Folder Owner** (for Agent version 4.3.1 and higher), select **Yes** if you want the Agent to fetch the OS file (or folder, depending on the File Watch Mode) creator and add the information as a metadata to the file during upload. Select **No** if you don't want the OS file or folder creator information added as metadata.

13. For **Archive Settings**, configure the following options based on your use case:

    * **(For FLA v4.3 and later)** If **File Watch Mode** is set to **file**, then the following read-only **Archive** information appears:
      * **Archive files to folder** (toggle)—indicates if archive settings are activated or not
      * **Archive to**—shows the root folder where archived files are stored
      * **Archive time and unit**—shows the amount of time after successful file upload
      * **Delete file from archive permanently** (toggle)—indicates if delete settings are activated or not
      * **Delete time and unit**—shows the amount of time that after a file has been archived and when it becomes eligible to be deleted

    For more information, see [Archive Settings](https://developers.tetrascience.com/docs/tetra-file-log-agent-installation-guide-version-44x#archive-settings).

14. Choose **Overwrite Local with Existing Cloud Configuration**.

> 📘 NOTE
>
> If a **Cloud/Local Configuration is Out of Sync** message displays, then the Agent's cloud and local configurations are different. To review the differences, choose the **Review Cloud Configuration** and **Review Local Configuration** buttons. Based on the differences, you can decide to push the configuration or reject it.

# Test the Setup

To verify that the Agent is pulling data from the path you configured, see [Step 7: Test the Setup](https://developers.tetrascience.com/docs/upload-instrument-data-using-a-tetra-file-log-agent#step-7-test-the-setup) in the Upload Instrument Data Using a Tetra File-Log Agent quickstart guide.

# Documentation Feedback

Do you have questions about our documentation or suggestions for how we can improve it? [Start a discussion in TetraConnect Hub](https://tetrascience.zendesk.com/hc/en-us/community/topics/38259263466893-Documentation-Feedback). For access, see [Access the TetraConnect Hub](https://developers.tetrascience.com/docs/access-the-tetrascience-knowledge-base).

> 📘 NOTE
>
> Feedback isn't part of the official TetraScience product documentation. TetraScience doesn't warrant or make any guarantees about the feedback provided, including its accuracy, relevance, or reliability. All feedback is subject to the terms set forth in the [TetraConnect Hub Community Guidelines](https://tetrascience.zendesk.com/hc/en-us/articles/26916126183309-TetraConnect-Hub-Community-Guidelines).