Tetra Chromeleon Agent - Which Report Variables Can Have Errors?

In agent v2.0.x, these report variables may have errors in RAW JSON

RAW JSON KeyChromeleon CategoryChromeleon Variable
AmountPeak GroupAmount
GroupPeak GroupPeak Group(s)
GroupAmountPeak ResultsGroup Amount
LevelToleranceLowAmountPeak ResultsLevel Tolerance Low Amount
PeakToValleyRatioPeak ResultsPeak to Valley Ratio
RiPeak ResultsRetention Index
ConfidenceIntervalLowerLimitPeak CalibrationLower Confidence Limit
PredictionIntervalLowerLimitPeak CalibrationLower Prediction Limit
CalPointDistPeak CalibrationResidual for Cal. Point x
ConfidenceIntervalUpperLimitPeak CalibrationUpper Confidence Limit
PredictionIntervalUpperLimitPeak CalibrationUpper Prediction Limit
ConfirmationChmPeak Purity and IdentificationConfirmation Chromatogram
ConfirmationPeakPeak Purity and IdentificationConfirmation Peak
IstdChmPeak Purity and IdentificationISTD Chromatogram
IstdPeakPeak Purity and IdentificationISTD Peak
HitMassSpecPeak Purity and IdentificationMSLS Hit
ConfirmationRatioPeak Purity and IdentificationPeak Confirmation Ratio
MspecPeak Purity and IdentificationPeak Mass Spectrum
RefMsMatchPeak Purity and IdentificationReference Mass Spectrum Match
RefMatchPeak Purity and IdentificationReference Spectrum Match
RsdRatioPeak Purity and IdentificationRSD Peak Ratio
AmountDifferencePeak Purity - Composite ScoringAmount Difference
IsotopicDotProductPeak Purity - Composite ScoringIsotopic Dot Product
MassAccuracyPeak Purity - Composite ScoringMass Accuracy
PeakApexAlignmentPeak Purity - Composite ScoringPeak Apex Alignment
ScorePeak Purity - Composite ScoringScore
BlankRunInjectionProcessing MethodBlank Run Injection Record
FixedCalibrationUpdateOperatorProcessing MethodLast Fixed Calibration Update Operator
FixedCalibrationUpdateTimeProcessing MethodLast Fixed Calibration Update Date & Time
SelectedComponentProcessing MethodSelect Component in the Component Table
SstTcProcessing MethodSelect Test Case
PeakGroupProcessing MethodSelect Peak Group
SlsProcessing MethodSpectra Library Screening Parameters
RefMsSettingsComponentReference Mass Spectrum Settings
ReferenceSpectrumComponentReference Spectrum
RiComponentRetention Index
AutoNoiseChromatogramAuto Noise (Cobra)
AdductMassesInjectionAdduct Masses
AdductsInjectionAdducts
CalculatedMassInjectionCalculated Mass
ChemicalFormulaAndAdductMassesInjectionChemical Formula and Adduct Masses
LevelCheckInjectionLevel Check
LockVersionInjectionLock Version
RetentionTimeStandardStatusInjectionRetention Time Standard Status
TestCaseOverallResultInjectionTest Case Overall Result
BaselineCorrectionInfoSpectrumBaseline Correction
PropertyValueSpectrumProperty Value
PropertyUnitSpectrumProperty Unit
SubRangeSpectrumRestrict Wavelength Range
SigValueSpectrumSignal Value
FixedBlcorrectionRangeMin

FixedBlcorrectionRangeMax
UV SettingsMinimum/Maximum of Fixed Baseline Correction Range
DetectedMassAccuraciesMass SpectrumDetected Mass Accuracies
DetectedMassesMass SpectrumDetected Masses
MassDetectedMass SpectrumMass Detected
MassDetectedFormulasMass SpectrumMass Detected Formulas
RelIntensityMass SpectrumRelative Intensity
IsLibraryUsedMS Library ScreeningIs MS Library Used
LibraryMS Library ScreeningMS Library
AbsoluteThresholdMS SettingsAbsolute Noise Reduction Threshold
FixedBlcorrectionRangeMaxMS SettingsMaximum of Fixed Baseline Correction Range
FixedBlcorrectionRangeMinMS SettingsMinimum of Fixed Baseline Correction Range